Condensation Call-Backs: Knowing a Wet Loft from a Leaking Roof

13 November 2026

The call tends to come in the first cold spell after a reroof. The householder has been up through the hatch, found the underside of the new membrane wet and assumed the roof is letting water in. Sometimes it is. When water appears after a run of dry, frosty nights, though, it has most likely come from the house below, and often from washing left to dry on radiators.

Reading the Loft on a Cold Morning

A leak and condensation leave different marks, and a visit early in the day after a clear, cold night shows the difference best. Condensation spreads across the underlay as a fine film of droplets over a wide area, with damp running down the rafters, rust on the nail tips and dark staining around the hatch. A leak stays local to a slipped tile, a valley, a flashing or a vent pipe, and it shows up after heavy rain. Insulation packed tight into the eaves is worth checking on the same visit, because it blocks the low-level airflow the roof was designed around.

Gaps at downlights, around the soil pipe and at an unsealed hatch show where warm air is getting in. Photograph them before anything is moved.

What BS 5250 Expects

BS 5250:2021, Management of moisture in buildings, is the code a pitched roof is judged against. On a cold roof, eaves-to-eaves ventilation is acceptable where the span is 10 m or less and the pitch is below 35 degrees. Beyond either limit, add high-level ventilation equal to a continuous 5 mm gap along the ridge. A vapour-permeable underlay does not replace ventilation, and where nobody can say which underlay is fitted, manufacturers’ technical guidance is to treat it as a non-breather.

Moisture from the Rooms Below

A roof ventilated to standard can still run wet if the house below puts a lot of moisture into the air, and laundry is the source householders most often overlook. In research from The Glasgow School of Art, one load of washing gave off around two litres of water as it dried, and washing hung on radiators in a room with poor ventilation produced as much as a third of the moisture in that room.

Householders can cut down on wet loads straight away, as plenty of what goes into the machine has been worn only once, an office shirt or a jacket, say. Steamed on a hanger, a garment like that is dampened at the surface rather than soaked through, and it goes back in the wardrobe without ever reaching the airer. Anyone who wants to see the options, from steam generators that handle a week of shirts to handheld steamers, will find a range at https://www.laurastar.co.uk/.

The washing that still has to dry indoors is better kept to one room with the door shut and the extractor running. The same Glasgow study ties the extra moisture to mould growth and dust.

Share article

Sign Up to
Roofing Today

Stay up to date with all of the latest news from Roofing Today by signing up to our weekly Bulletins…

 

Check out the latest issue

127 November – December 2026